Mean Well Enterprises Co. Ltd., located in Tajwanie is a leader in design and manufacturing of impulse energy sources, which include AC/DC power supplies, DC/DC converters, DC/AC inverters and battery chargers. Offered devices are meant to be mounted inside of existng electronic systems (Open Frame series), on DIN rail or used as standalone products. As company grew, product portfolio grew even faster reaching around 2000 models. With distribution network widely developed around the world, and long time experience in development and manufacturing makes Mean Well a very strong company, which gives it's customers feeling of safety and stability. From 1994 company is managed according to ISO 9001, while it's products conform with TUV, UL, CSA and S MARK. All devices shipped to EU are manufactured in lead-free technology (RoHS). |
Output | |
---|---|
DC Voltage | 12V |
Rated current | 10A |
Current Range | 0÷10A |
Rated Power | 120W |
Ripple & noise (max.) | 120mVp-p |
Voltage adjustment range | 12÷15V |
Voltage tolerance | ±1.5% |
Line regulation | ±0.5% |
Load regulation | ±0.5% |
Setup & rise time |
2000ms & 70ms/400VAC at full load, 2000ms & 70ms/230VAC at full load |
Hold up time (typ.) |
50ms/400VAC at full load, 50ms/230VAC at full load |
Input | |
Voltage range |
180÷550VAC, 254÷780VDC |
Frequency range | 47÷63Hz |
Efficiency (typ.) | 89,5% |
AC current (typ.) |
0.55A/115VAC, 1.2A/230VAC |
Inrush current (typ.) | 50A |
Leakage current | <3,5mA/530VAC |
Protection | |
Overload |
105%÷130% rated output power, protection type - constant current limiting - recovers automatically after fault condition is removed |
Overvoltage |
16÷18V, protection type - shut down o/p voltage & re-power on to recover |
Over temperature |
105°C ±5°C (TSW1) detect on heatsink of power transistor, protection type - shut down o/p voltage & re-power on to recover |
Environment | |
Working temperature | -25°C ÷ 70°C |
Working humidity | 20÷95% RH non-condensing |
Storage temperature | -40°C ÷ 85°C |
Storage Humidity | 10÷95% RH |
Temperature coefficient | ±0.03%/°C (0÷50°C) |
Vibration (component) |
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes |
Vibration (mounting) | compliance to IEC60068-2-6 |
Safety & EMC | |
Safety standards |
UL508, UL60950-1, TUV EN60950-1 |
Withstand voltage |
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC |
Isolation resistance |
I/P-O/P 100MΩ/500VDC, I/P-FG 100MΩ/500VDC, O/P-FG 100MΩ/500VDC |
EMI conduction & radiation |
EN55011, EN55022 (CISPR22), EN61204-3 Class B |
Harmonic current |
EN61000-3-2, EN61000-3-3 |
EMS immunity |
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level criteria A |
Others | |
MTBF | min. 268000h MIL-HDBK-217F (25°C) |
Dimension (W x H x D) | 40mm x 125,2mm x 113,5mm |
Weight | 0,65kg |
Output | |
---|---|
DC Voltage | 24V |
Rated current | 10A |
Current Range | 0÷10A |
Rated Power | 240W |
Ripple & noise (max.) | 150mVp-p |
Voltage adjustment range | 24÷28V |
Voltage tolerance | ±1.0% |
Line regulation | ±0.5% |
Load regulation | ±1.0% |
Setup & rise time |
800ms & 150ms/400VAC at full load, 1500ms & 150ms/230VAC at full load |
Hold up time (typ.) |
18ms/400VAC at full load, 18ms/230VAC at full load |
Input | |
Voltage range |
180÷550VAC, 254÷780VDC |
Frequency range | 47÷63Hz |
Efficiency (typ.) | 91% |
AC current (typ.) |
1A/400VAC, 2A/230VAC |
Inrush current (typ.) | 50A |
Leakage current | <3,5mA/530VAC |
Protection | |
Overload |
105%÷130% rated output power, protection type - constant current limiting - recovers automatically after fault condition is removed |
Overvoltage |
29÷33V, protection type - shut down o/p voltage & re-power on to recover |
Over temperature |
90°C ±5°C (TSW1) detect on heatsink of power transistor, protection type - shut down o/p voltage & re-power on to recover |
Environment | |
Working temperature | -30°C ÷ 70°C |
Working humidity | 20÷95% RH non-condensing |
Storage temperature | -40°C ÷ 85°C |
Storage Humidity | 10÷95% RH |
Temperature coefficient | ±0.03%/°C (0÷50°C) |
Vibration (component) |
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes |
Vibration (mounting) | compliance to IEC60068-2-6 |
Safety & EMC | |
Safety standards |
UL508, UL60950-1, TUV EN60950-1 |
Withstand voltage |
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC |
Isolation resistance |
I/P-O/P 100MΩ/500VDC, I/P-FG 100MΩ/500VDC, O/P-FG 100MΩ/500VDC |
EMI conduction & radiation |
EN55011, EN55022 (CISPR22), EN61204-3 Class B |
Harmonic current |
EN61000-3-2, EN61000-3-3 |
EMS immunity |
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level criteria A |
Others | |
MTBF | min. 268000h MIL-HDBK-217F (25°C) |
Dimension (W x H x D) | 63mm x 125,2mm x 113,5mm |
Weight | 1,06kg |
Output | |
---|---|
DC Voltage | 24V |
Rated current | 20A |
Current Range | 0÷20A |
Rated Power | 480W |
Ripple & noise (max.) | 100mVp-p |
Voltage adjustment range | 24÷28V |
Voltage tolerance | ±1.0% |
Line regulation | ±0.5% |
Load regulation | ±1.0% |
Setup & rise time |
800ms & 150ms/400VAC at full load, 2000ms & 150ms/230VAC at full load |
Hold up time (typ.) |
18ms/400VAC at full load, 16ms/230VAC at full load |
Input | |
Voltage range |
180÷550VAC, 254÷780VDC |
Frequency range | 47÷63Hz |
Efficiency (typ.) | 92% |
AC current (typ.) |
1.6A/400VAC, 4A/230VAC |
Inrush current (typ.) | 50A |
Leakage current | <3,5mA/530VAC |
Protection | |
Overload |
105%÷130% rated output power, protection type - constant current limiting - recovers automatically after fault condition is removed |
Overvoltage |
29÷33V, protection type - shut down o/p voltage & re-power on to recover |
Over temperature |
95°C ±5°C (TSW1) detect on heatsink of power transistor, protection type - shut down o/p voltage & re-power on to recover |
Environment | |
Working temperature | -30°C ÷ 70°C |
Working humidity | 20÷95% RH non-condensing |
Storage temperature | -40°C ÷ 85°C |
Storage Humidity | 10÷95% RH |
Temperature coefficient | ±0.03%/°C (0÷50°C) |
Vibration (component) |
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes |
Vibration (mounting) | compliance to IEC60068-2-6 |
Safety & EMC | |
Safety standards |
UL508, UL60950-1, TUV EN60950-1 |
Withstand voltage |
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC |
Isolation resistance |
I/P-O/P 100MΩ/500VDC, I/P-FG 100MΩ/500VDC, O/P-FG 100MΩ/500VDC |
EMI conduction & radiation |
EN55011, EN55022 (CISPR22), EN61204-3 Class B |
Harmonic current |
EN61000-3-2, EN61000-3-3 |
EMS immunity |
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-2 (EN50082-2), heavy industry level criteria A |
Others | |
MTBF | min. 268000h MIL-HDBK-217F (25°C) |
Dimension (W x H x D) | 85.5mm x 125.2mm x 128.5mm |
Weight | 1.7kg |
Output | |
---|---|
DC Voltage | 24V |
Rated current | 0.42A |
Current Range | 0÷0.42A |
Rated Power | 10W |
Ripple & noise (max.) | 150mVp-p |
Voltage tolerance | ±2.0% |
Line regulation | ±1.0% |
Load regulation | ±2.0% |
Setup & rise time |
500ms & 30ms/230VAC at full load, 1000ms & 30ms/115VAC at full load |
Hold up time (typ.) |
120ms/230VAC at full load, 25ms/115VAC at full load |
Input | |
Voltage range |
85÷264VAC, 120÷370VDC |
Frequency range | 47÷63Hz |
Efficiency (typ.) | 84% |
AC current (typ.) |
0.33A/115VAC, 0.21A/230VAC |
Inrush current (typ.) |
35A/115VAC cold start, 70A/230VAC cold start |
Leakage current | <1mA/240VAC |
Protection | |
Overload |
above 105% rated output power, protection type - Hiccup mode - recovers automatically after fault condition is removed |
Overvoltage |
27.6÷32.4V, protection type - shut down o/p voltage & re-power on to recover |
Function | |
DC OK active signal | 18÷27V/20mA |
Environment | |
Working temperature | -20°C ÷ 70°C |
Working humidity | 20÷90% RH non-condensing |
Storage temperature | -40°C ÷ 85°C |
Storage Humidity | 10÷95% RH |
Temperature coefficient | ±0.03%/°C (0÷50°C) |
Vibration (component) |
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes |
Vibration (mounting) | compliance to IEC60068-2-6 |
Safety & EMC | |
Safety standards |
UL508, TUV EN60950-1, NEC class 2 / LPS |
Withstand voltage |
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC |
Isolation resistance |
I/P-O/P 100MΩ/500VDC, I/P-FG 100MΩ/500VDC, O/P-FG 100MΩ/500VDC |
EMI conduction & radiation |
EN55011, EN55022 (CISPR22), EN61204-3 Class B |
Harmonic current |
EN61000-3-2, EN61000-3-3 |
EMS immunity |
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-1, EN61204-3, light industry level criteria A |
Others | |
MTBF | min. 584000h MIL-HDBK-217F (25°C) |
Dimension (W x H x D) | 22.5mm x 90mm x 100mm |
Weight | 0.17kg |
Warranty | 3 years |
Output | |
---|---|
DC Voltage | 24V |
Rated current | 1A |
Current Range | 0÷1A |
Rated Power | 24W |
Ripple & noise (max.) | 150mVp-p |
Voltage adjustment range | 21.6÷26.4V |
Voltage tolerance | ±1.0% |
Line regulation | ±1.0% |
Load regulation | ±1.0% |
Setup & rise time |
500ms & 30ms/230VAC at full load, 1000ms & 30ms/115VAC at full load |
Hold up time (typ.) |
50ms/230VAC at full load, 20ms/115VAC at full load |
Input | |
Voltage range |
85÷264VAC, 120÷370VDC |
Frequency range | 47÷63Hz |
Efficiency (typ.) | 84% |
AC current (typ.) |
0.55A/115VAC, 0.35A/230VAC |
Inrush current (typ.) |
20A/115VAC cold start, 40A/230VAC cold start |
Leakage current | <1mA/240VAC |
Protection | |
Overload |
105%÷160% rated output power, protection type - constant current limiting - recovers automatically after fault condition is removed |
Overvoltage |
27.6÷32.4V, protection type - shut down o/p voltage & re-power on to recover |
Function | |
DC OK active signal | 18÷27V/20mA |
Environment | |
Working temperature | -20°C ÷ 70°C |
Working humidity | 20÷90% RH non-condensing |
Storage temperature | -40°C ÷ 85°C |
Storage Humidity | 10÷95% RH |
Temperature coefficient | ±0.03%/°C (0÷50°C) |
Vibration (component) |
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes |
Vibration (mounting) | compliance to IEC60068-2-6 |
Safety & EMC | |
Safety standards |
UL508, TUV EN60950-1, NEC class 2 / LPS |
Withstand voltage |
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC |
Isolation resistance |
I/P-O/P 100MΩ/500VDC, I/P-FG 100MΩ/500VDC, O/P-FG 100MΩ/500VDC |
EMI conduction & radiation |
EN55011, EN55022 (CISPR22), EN61204-3 Class B |
Harmonic current |
EN61000-3-2, EN61000-3-3 |
EMS immunity |
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-1, EN61204-3, light industry level criteria A |
Others | |
MTBF | min. 236900h MIL-HDBK-217F (25°C) |
Dimension (W x H x D) | 22.5mm x 90mm x 100mm |
Weight | 0.19kg |
Warranty | 3 years |
Output | |
---|---|
DC Voltage | 24V |
Rated current | 1.7A |
Current Range | 0÷1.7A |
Rated Power | 40.8W |
Ripple & noise (max.) | 150mVp-p |
Voltage adjustment range | 24÷30V |
Voltage tolerance | ±1.0% |
Line regulation | ±1.0% |
Load regulation | ±1.0% |
Setup & rise time |
500ms & 30ms/230VAC at full load, 500ms & 30ms/115VAC at full load |
Hold up time (typ.) |
50ms/230VAC at full load, 20ms/115VAC at full load |
Input | |
Voltage range |
85÷264VAC, 120÷370VDC |
Frequency range | 47÷63Hz |
Efficiency (typ.) | 88% |
AC current (typ.) |
1.1A/115VAC, 0.7A/230VAC |
Inrush current (typ.) |
30A/115VAC cold start, 60A/230VAC cold start |
Leakage current | <1mA/240VAC |
Protection | |
Overload |
105%÷150% rated output power, protection type - constant current limiting - recovers automatically after fault condition is removed |
Overvoltage |
31.2÷36V, protection type - shut down o/p voltage & re-power on to recover |
Function | |
DC OK signal relay contact rating (max.) | 30V/1A resistive |
Environment | |
Working temperature | -20°C ÷ 70°C |
Working humidity | 20÷90% RH non-condensing |
Storage temperature | -40°C ÷ 85°C |
Storage Humidity | 10÷95% RH |
Temperature coefficient | ±0.03%/°C (0÷50°C) |
Vibration (component) |
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes |
Vibration (mounting) | compliance to IEC60068-2-6 |
Safety & EMC | |
Safety standards |
UL508, UL60950-1, TUV EN60950-1, NEC class 2 / LPS |
Withstand voltage |
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC |
Isolation resistance |
I/P-O/P 100MΩ/500VDC 25°C 70%RH, I/P-FG 100MΩ/500VDC 25°C 70%RH, O/P-FG 100MΩ/500VDC 25°C 70%RH |
EMI conduction & radiation |
EN55011, EN55022 (CISPR22), EN61204-3 Class B |
Harmonic current |
EN61000-3-2, EN61000-3-3 |
EMS immunity |
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level criteria A |
Others | |
MTBF | min. 301700h MIL-HDBK-217F (25°C) |
Dimension (W x H x D) | 40mm x 90mm x 100mm |
Weight | 0.3kg |
Output | |
---|---|
DC Voltage | 24V |
Rated current | 2.5A |
Current Range | 0÷2.5A |
Rated Power | 60W |
Ripple & noise (max.) | 150mVp-p |
Voltage adjustment range | 24÷30V |
Voltage tolerance | ±1.0% |
Line regulation | ±1.0% |
Load regulation | ±1.0% |
Setup & rise time |
500ms & 30ms/230VAC at full load, 500ms & 30ms/115VAC at full load |
Hold up time (typ.) |
50ms/230VAC at full load, 20ms/115VAC at full load |
Input | |
Voltage range |
85÷264VAC, 120÷370VDC |
Frequency range | 47÷63Hz |
Efficiency (typ.) | 88% |
AC current (typ.) |
1.8A/115VAC, 1A/230VAC |
Inrush current (typ.) |
30A/115VAC cold start, 60A/230VAC cold start |
Leakage current | <1mA/240VAC |
Protection | |
Overload |
105%÷150% rated output power, protection type - constant current limiting - recovers automatically after fault condition is removed |
Overvoltage |
31.2÷36V, protection type - shut down o/p voltage & re-power on to recover |
Function | |
DC OK signal relay contact rating (max.) | 30V/1A resistive |
Environment | |
Working temperature | -20°C ÷ 70°C |
Working humidity | 20÷90% RH non-condensing |
Storage temperature | -40°C ÷ 85°C |
Storage Humidity | 10÷95% RH |
Temperature coefficient | ±0.03%/°C (0÷50°C) |
Vibration (component) |
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes |
Vibration (mounting) | compliance to IEC60068-2-6 |
Safety & EMC | |
Safety standards |
UL508, UL60950-1, TUV EN60950-1, NEC class 2 / LPS |
Withstand voltage |
I/P-O/P 3kVAC, I/P-FG 1.5kVAC, O/P-FG 0.5kVAC |
Isolation resistance |
I/P-O/P 100MΩ/500VDC 25°C 70%RH, I/P-FG 100MΩ/500VDC 25°C 70%RH, O/P-FG 100MΩ/500VDC 25°C 70%RH |
EMI conduction & radiation |
EN55011, EN55022 (CISPR22), EN61204-3 Class B |
Harmonic current |
EN61000-3-2, EN61000-3-3 |
EMS immunity |
EN61000-4-2/3/4/5/6/8/11, ENV50204, EN55024, EN61000-6-2, EN61204-3, heavy industry level criteria A |
Others | |
MTBF | min. 299200h MIL-HDBK-217F (25°C) |
Dimension (W x H x D) | 40mm x 90mm x 100mm |
Weight | 0.33kg |
Output | |
---|---|
DC Voltage | 24V |
Rated current | 0.63A |
Rated Power | 15W |
Ripple & noise (max.) | 150mVp-p |
Voltage adjustment range | 21.6÷29.0V |
Voltage tolerance | ±1.0% |
Line regulation | ±1.0% |
Load regulation | ±1.0% |
Input | |
Voltage range |
85÷264VAC, 120÷370VDC |
Efficiency (typ.) | 86% |
Protection | |
Overload |
105%÷160% rated output power, protection type - constant current limiting - recovers automatically |
Overvoltage |
115%÷150%, protection type - shut down , clamp by zener diode |
Environment | |
Working temperature | -30°C ÷ 70°C |
Vibration (component) |
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes |
Safety & EMC | |
Safety standards |
UL62368-1, UL508, TUV EN61558-2-16, IEC62368-1, EAC Tp TC 040, BSMI CNS14336-1 approved |
Withstand voltage | I/P-O/P 4kVAC |
EMC Standards |
EN55032 class B, EN61000-3-2,33, EN61000-6-2, EN61000-4-2,3,4,5,6,8,11, EN61204-3 |
Others | |
MTBF | min. 441500h MIL-HDBK-217F (25°C) |
Dimension (W x H x D) | 17.5mm x 90mm x 5.5mm |
Output | |
---|---|
DC Voltage | 24V |
Rated current | 1.5A |
Current Range | 0÷1.5A |
Rated Power | 30W |
Ripple & noise (max.) | 150mVp-p |
Voltage adjustment range | 21.6÷29.0V |
Voltage tolerance | ±1.0% |
Line regulation | ±1.0% |
Load regulation | ±1.0% |
Input | |
Voltage range |
85÷264VAC, 120÷370VDC |
Efficiency (typ.) | 89% |
Protection | |
Overload |
105%÷160% rated output power, protection type - constant current limiting - recovers automatically |
Overvoltage |
115%÷150%, protection type - shut down & re-power on to recover |
Environment | |
Working temperature | -30°C ÷ 70°C |
Vibration (component) |
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes |
Safety & EMC | |
Safety standards |
UL62368-1, UL508, TUV EN61558-2-16, IEC62368-1, EAC Tp TC 040, BSMI CNS14336-1 approved |
Withstand voltage | I/P-O/P 4kVAC |
EMC Standards |
EN55032 class B, EN61000-3-2,33, EN61000-6-2, EN61000-4-2,3,4,5,6,8,11, EN61204-3 |
Others | |
MTBF | min. 441500h MIL-HDBK-217F (25°C) |
Dimension (W x H x D) | 35mm x 90mm x 5.5mm |
Output | |
---|---|
DC Voltage | 24V |
Rated current | 2.5A |
Current Range | 0÷2.5A |
Rated Power | 60W |
Ripple & noise (max.) | 150mVp-p |
Voltage adjustment range | 21.6÷29.0V |
Voltage tolerance | ±1.0% |
Line regulation | ±1.0% |
Load regulation | ±1.0% |
Input | |
Voltage range |
85÷264VAC, 120÷370VDC |
Efficiency (typ.) | 60% |
Protection | |
Overload |
105%÷160% rated output power, protection type - constant current limiting - recovers automatically |
Overvoltage |
115%÷150%, protection type - shut down & re-power on to recover |
Environment | |
Working temperature | -30°C ÷ 70°C |
Vibration (component) |
10÷500Hz, 2G 10min./1cycle, 60min. each along X Y Z axes |
Safety & EMC | |
Safety standards |
UL62368-1, UL508, TUV EN61558-2-16, IEC62368-1, EAC Tp TC 040, BSMI CNS14336-1 approved |
Withstand voltage | I/P-O/P 4kVAC |
EMC Standards |
EN55032 class B, EN61000-3-2,33, EN61000-6-2, EN61000-4-2,3,4,5,6,8,11, EN61204-3 |
Others | |
MTBF | min. 441500h MIL-HDBK-217F (25°C) |
Dimension (W x H x D) | 52.5mm x 90mm x 5.5mm |