Physical Ports | |
---|---|
LC connector | 4 Duplex Multi-mode LC connector |
Fiber Ethernet | |
Optical Fiber | Multi-mode - 50/125μm or 62,5/125μm |
Operating Wavelength | 780÷1350 nm |
Insert loss | <1.0 dB |
Switch time | < 10ms |
DIP Switch Settings | DIP Swicth No.1 - Power-1 failed warning detection – (On) relay enable (Off) relay disable |
DIP Switch No.2 - Power-2 failed warning detection – (On) relay enable (Off) relay disable | |
LED Indicators | |
Power indicator | Green - Ready LED x 2 |
Normal indicator | Green On - Operated in normal mode |
Fault indicator | Amber - Indicates power failure occurred |
Fault contact | |
Relay | Relay output for power failure warning |
Power | |
Input power | Dual 12~48 VDC power inputs at DC-Jack and 4-pin terminal block |
Power consumption (typical) | 2.7W |
Overload current protection | present |
Reverse polarity protection | present |
Physical Characteristic | |
Enclosure | IP-30 |
Dimension (W x D x H) | 26.1mm x 94.9mm x 144.3mm |
Weight | 405g |
Environmental | |
Storage Temperature | -40÷85°C(-40÷185°F) |
Operating Temperature | -20÷70°C (-4÷158°F) |
Operating Humidity | 10%÷90% Non-condensing |
Regulatory approvals | |
EMI |
FCC Part 15, CISPR (EN55022) class A |
EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
Shock | IEC60068-2-27 |
Free Fall | IEC60068-2-32 |
Vibration | IEC60068-2-6 |
MTBF (Hours) (MIL-HDBK-217F2, GB, GC, 25°C) | 1,246,758 |
Warranty | |
Warranty period | 1 years |
Physical Ports | |
---|---|
LC connector | 4 Duplex Single-mode LC connector |
Fiber Ethernet | |
Optical Fiber | Single-mode - 9/125μm |
Operating Wavelength | 1260÷1570 nm |
Insert loss | 1.6 dB |
Switch time | < 10ms |
DIP Switch Settings | DIP Swicth No.1 - Power-1 failed warning detection – (On) relay enable (Off) relay disable |
DIP Switch No.2 - Power-2 failed warning detection – (On) relay enable (Off) relay disable | |
LED Indicators | |
Power indicator | Green - Ready LED x 2 |
Normal indicator | Green On - Operated in normal mode |
Fault indicator | Amber - Indicates power failure occurred |
Fault contact | |
Relay | Relay output for power failure warning |
Power | |
Input power | Dual 12~48 VDC power inputs at DC-Jack and 4-pin terminal block |
Power consumption (typical) | 2.7W |
Overload current protection | present |
Reverse polarity protection | present |
Physical Characteristic | |
Enclosure | IP-30 |
Dimension (W x D x H) | 26.1mm x 94.9mm x 144.3mm |
Weight | 405g |
Environmental | |
Storage Temperature | -40÷85°C(-40÷185°F) |
Operating Temperature | -20÷70°C (-4÷158°F) |
Operating Humidity | 10%÷90% Non-condensing |
Regulatory approvals | |
EMI |
FCC Part 15, CISPR (EN55022) class A |
EMS |
EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
Shock | IEC60068-2-27 |
Free Fall | IEC60068-2-32 |
Vibration | IEC60068-2-6 |
MTBF (Hours) (MIL-HDBK-217F2, GB, GC, 25°C) | 1,246,758 |
Warranty | |
Warranty period | 1 years |
Page 12 of 12
|