Installation |
Using patch-cable RJ-11 the sensor is connected to an analog input of any system unit. Determination of sensor's type and connection occur automatically. One of devices in the kit, for example, magnet, is mounted on a door; the second device is mounted on a jamb of a door. At opening a door contact is disconnected, and system of monitoring receives notification on opening. The first sensor is connected using patch-cable RJ-11 to an analog input of the system unit, the consequent sensor is connected via patch-cable RJ-11 to an output of the first sensor and so on. |
---|---|
Set includes |
Contact sensor, magnet, 4-wired patch cable RJ-11 (2m), two screws 4.8×16mm, 2 screws M5 and 2 nuts, bracket, double sided sticker. |
Max. distance | 150m |
Net weight | 106g |
Dimensions (LHW) | Two compact devices with dimensions 60×18×18mm |
Voltage measured | 0-75V |
---|---|
Accuracy of measurement | 1% |
Max. distance m | 50m |
Net weight | 100g |
Dimensions (LHW) | 60×18×18 mm |
Voltage measured | 0-246V AC |
---|---|
Accuracy of measurement | 1% |
Max. distance m | 100m |
Net weight | 125g |
Dimensions (HxWxD) | 90.2×36.3×57.5mm |
Technical specifications | |
---|---|
Measured humidity range | 10-95% RH |
Accuracy | 5%RH |
Working temperature | -10 .. +80°C |
Features | |
Installation | On the bottom there is a ledge with Ø4.5mm and height 1mm and a Ø5mm mounting hole fpr mounting the sensor. |
5mm from it for fastening the sensor using 4.8×16 mm screw. | |
Connection | Humidity sensor contains RJ-11 jack and is connected to an analog input of any system unit. Determination of type of sensor and connection occur automatically. |
Supply includes |
Sensor, 4-wired patch cable RJ11 (2m), 4.8×16mm screw, double sided sticker. |
Net weight | 60g |
Dimensions | 60×18×18mm |
Max distance | 150m |
Technical specifications | |
---|---|
PIR detection angle | 110° |
Max. detection distance | 50 m |
Features | |
Installation | On the bottom there is a mounting slot for fastening the sensor with a plastic bracket. |
Connection |
Motion sensor contains RJ-11 jack and is connected to an analog input of any system unit. Determination of sensor's type and connection occur automatically. To adjust sensitivity, read manual. To change cable connection, open the cover and read manual. |
Dimensions (LxHxW) | 105×57×40mm |
Net weight | 133g |
Supply includes |
Sensor, cable RJ11 2m, 4.8×16mm screw, 2-pin terminal strip type TBW-5-2p, double sided sticker. |
Technical specifications | |
---|---|
Operating temperature | -50...+105°C |
Accuracy | 3°C |
Max. distance | 100m |
Features | |
Installation |
An all-weather 2-pair UTP cable of 15m emerges from the cylinder. After installation of cylinder outside of a building, the cable must be placed to reach the system unit. |
Connection | After installation RJ-11 connector is connected to an analog input of any system unit. Determination of type of sensor and connection occur automatically. |
Supply includes | 4-wired cable RJ11 (15m) with sensor head |
Net weight | 340g |
Dimensions (LHW) | Device has a shape of a Ø7×23mm cylinder |
Technical specifications | |
---|---|
PIR detection angle | 120° |
Sensing distance | maximum is 12 meters |
Frequency Range | 5.725GHz-5.875GHz |
Max. detection distance | 100 m |
Features | |
Installation | On the bottom there is a mounting slot for fastening the sensor with a plastic bracket. |
Connection |
Motion sensor contains RJ-11 jack and is connected to an analog input of any system unit. Determination of sensor's type and connection occur automatically. To adjust sensitivity, read manual. To change cable connection, open the cover and read manual. |
Supply includes |
Sensor, cable RJ11 2m, holder |
Technical specifications | |
---|---|
Sensitivity | 0,05 - 0,2 db/m |
Features | |
Installation | On the bottom there are Ø5mm mounting holes for fastening the smoke sensor to the surface by 4.8×20mm screws or/and bracket and M4 screws. |
Connection |
Detector's jack RJ-11 is connected to an analog input of any system unit using patch-cable RJ-11. Determination of the sensor's type and connection occur automatically. The monitoring system allows to connect several smoke detectors into a linear circuit. For this purpose each detector has two jacks RJ-11 input and output. The first is connected to an analog input of the system unit using a patch-cable RJ-11, the consequent is connected via patch-cable RJ-11 to an output of the first detector and so on. as one sensor with one address. |
Supply includes |
Detector, 4-wired cable RJ11 (2m), 2 screws and 2 nuts M4, 2 screws 4.8×20mm, bracket, double sided sticker. |
Net weight | 290g |
Dimensions (LHW) | Ø100×45 |
Max distance | 150m |
Technical specifications | |
---|---|
Temperature range | -10… +80°C |
Max. distance | 100 m |
Connection | Connector RJ12 is connected to an analog input of any system unit. Determination of sensor's type and connection occur automatically. |
Set includes |
Sensor, adapter, 4-wired cable RJ-12 (2m) |
Net weight | 60g |
Dimensions (LHW) | 60×18×18mm |
Technical specifications | |
---|---|
Operating temperature | -10 ÷ 80°C |
Accuracy | 1°C |
Features | |
Installation | On the bottom there is a ledge with Ø4.5mm and height 1mm and a Ø5mm mounting hole for fastening the sensor using a 4.8×16 mm screw. |
Connection | Temperature sensor contains RJ-11 jack and is connected to an analog input of a system unit. Determination of type of sensor and connection occur automatically. |
Supply includes |
Sensor, 4-wired patch cable RJ11 (2m), 4.8×16mm screw, double sided sticker. |
Net weight | 50g |
Dimensions (LHW) | 60×18×18mm |
Max distance | 100m |
Page 2 of 7
|